pictures/imod_logo.png

iMOD User Manual version 4.4 (html)


10.16Data Set 16: Parameter Estimation – Batch Settings

Data Set 16

Apply PE_NBATCH times (see Date Set 14)
B_FRACTION,B_BATCHFILE,B_OUTFILE

B_FRACTION

Enter the fraction for the results from the current batch files. The entered fraction will be normalized together with the entered fraction for PE_TARGET(.) (see Data Set 14).

B_BATCHFILE

Enter the name of the batch file to be executed after each simulation, e.g. C:\BATCHFILES\FLOWLINES.BAT

B_OUTFILE

Enter the name of the output file from the batch file (B_BATCHFILE), e.g. C:\BATCHFILES\OUTPUT\FLOWLINES.OUT. The syntax of the file should be as follows:

N

Enter the number of records, e.g. N=2.

Z,V,H

Enter for each record i to N the measurement (Z), variance (V) and computed value (H). They can be entered in “free”-format. These values will be added to the total objective function value and included in the determination of the gradient.